Generators
|
EX
5500
|
EX
4D
|
EX
10D
|
EV
3610
|
EX
7
|
EU
10i
|
EU20i |
|
Max HP
|
13
|
9
|
20
|
13
|
1.8
|
1.8
|
3HP(100cc GX100) |
|
Fuel Tank Capacity (litres)
|
16.5
|
26
|
38
|
N/A
|
2.3
|
2.3
|
4.1 |
|
Continuous operating hours without
refuelling at rated load
|
5.5
|
13
|
11
|
*
See info Below
|
4.5
|
3.6/8.3
|
10.5 |
|
Output Voltage (V)
|
115/230
|
115/230
|
115/230
|
230
|
230
|
230
|
230 |
|
D.C. Output (V)
|
N/A
|
N/A
|
N/A
|
N/A
|
12V
6A
|
12V
8A
|
*option12V DC @ 6A |
|
AC Output (kW)
|
Rated
|
5.0
|
3.7
|
10
|
3.3
|
0.6
|
0.9
|
1.6 |
|
Maximum
|
5.5
|
4.1
|
-
|
3.6
|
0.7
|
1.0
|
2.0 |
|
AC Current (A)
|
43.5/21.7
|
32.2/16.1
|
43.5
|
14.3
|
2.6
|
3.9
|
|
|
Frequency (Hz)
|
50
|
50
|
50
|
50
|
50
|
50
|
50 |
|
Frequency stability on constant load (%)
+/-
|
1%
|
1%
|
1%
|
1%
|
1%
|
1%
|
1% |
|
Voltage stability on constant load (%) +/-
|
1%
|
1%
|
1%
|
1%
|
1%
|
1%
|
1% |
|
Overall dimensions
|
Length (mm)
|
965
|
1040
|
1390
|
650
|
450
|
450
|
510 |
|
Width (mm)
|
585
|
590
|
630
|
483
|
240
|
240
|
290 |
|
Height (mm)
|
645
|
705
|
815
|
391
|
380
|
380
|
425 |
|
Dry Weight (kg)
|
168
|
200
|
355
|
92
|
12
|
13
|
21 |
* Fuel consumption 2 litres per hour
**Welder 30V-250 DC, 25V-125A x2 DC
#Fully variable output up to 40A / Current limiter & auto-shut off
generator circuit protection
All the above generators are unity power factor, where the Kw output is
equivalent to kVA. They will tolerate loads with power factor down to 0.8
|