Generators
|
EM
3000
|
EM
4500
|
EM
4500SX*
|
EU
26i
|
EU
30iS
|
EX
4000
|
|
Max HP
|
8
|
11
|
11
|
4.1
|
5.1
|
11
|
|
Fuel Tank Capacity (litres)
|
17
|
17
|
17
|
13
|
13
|
19
|
|
Continuous operating hours without
refuelling at rated load
|
10.1
|
6.8
|
6.8
|
8.3/25
|
7.1/25
|
8.3
|
|
Output Voltage (V)
|
115/230
|
115/230
|
115/230
|
230
|
230
|
115/230
|
|
D.C. Output (V)
|
12V
8.3A
|
12V
8.3A
|
12V
8.3A
|
12V
10A
|
12V
12A
|
N/A
|
|
AC Output (kW)
|
Rated
|
2.7
|
4.0
|
4.0
|
2.4
|
2.8
|
3.5
|
|
Maximum
|
3.0
|
4.5
|
4.5
|
2.6
|
3.0
|
4.0
|
|
AC Current (A)
|
23.5/11.7
|
34.8/17.4
|
34.8/17.4
|
10.5
|
11.6
|
30.4/15.2
|
|
Frequency (Hz)
|
50
|
50
|
50
|
50
|
50
|
50
|
|
Frequency stability on constant load (%)
+/-
|
1%
|
1%
|
1%
|
1%
|
1%
|
1%
|
|
Voltage stability on constant load (%) +/-
|
1%
|
1%
|
1%
|
1%
|
1%
|
1%
|
|
Overall dimensions
|
Length (mm)
|
605
|
655
|
835
|
655
|
655
|
910
|
|
Width (mm)
|
495
|
510
|
655
|
445
|
480
|
530
|
|
Height (mm)
|
485
|
490
|
575
|
555
|
570
|
695
|
|
Dry Weight (kg)
|
62
|
78
|
87.5
|
54
|
61
|
122
|
*No battery supplied.
All the above generators are unity power factor, where the Kw output is
equivalent to kVA. They will tolerate loads with power factor down to 0.8
|